for Cold Climate Housing and much more

Found 144 results for the keyword ‘Walls’

  • Floating Shelves

    David from Kingston, Nova Scotia had a question about a floating shelf he was trying to build himself, but before answering his question I wanted to show some commercial 'floating' shelves that you can purchase.Just what is a 'floating' shelf? It is a shelf that appears to have little or not...
  • MYTH: VAPOUR BARRIERS CAUSE INSIDE CONDENSATION PROBLEMS.

    False. Vapour barriers, together with air barriers, prevent moisture from escaping into the walls. In this sense vapour barriers make you more aware of the quantity of moisture you have generated in your house. Condensation problems are caused by generating too much moisture and/or having too ...
  • WHY IS THERE FROST ON MY CEDAR WALL SHINGLES?

    Condensation or frost on cedar wall shingles on the shady side of the house, early in the morning on clear winter days, bothers many homeowners. They imagine that somehow vast quantities of water are escaping from the house. In fact, what is happening is that the surrounding air is warming up fa...
  • WHY IS THERE FROST ON THE RUG?

    On windy days, houses in the Prairies often develop a small frost line on the rug about an inch away from the wall on the north or west side of the house. Here the wind is succeeding in lowering the temperature of the most poorly insulated part of the house -- the floor boards. In most construct...
  • MYTH: INSULATION CAN BE ADDED BETWEEN EXISTING BRICK SIDING AND THE HOUSE.

    Do not fill the space between brick siding and the sheathing. First, this space is outside the sheathing and does not cause condensation, as does an air space inside the wall. (A small space between ordinary siding and the exterior insulation or between ordinary siding and sheathing is also perm...
  • HOW DO I INSULATE A SHALLOW BASEMENT?

    A basement that has more than 50 per cent of its height sticking out of the ground is not really a basement. The walls should be treated as ordinary, above-ground walls. The foundations should be treated as slab-on-grade to avoid frost problems. Interior/exterior insulation combinations can be u...
  • Weather Restrictions: Brick Mortar

    Connect to your favourite weather forecaster and look for the following conditions:   Category: Masonry     Product: Brick Mortar Temperature Limitations: Use above + 5 C (+40 F) Rain Limitations: No standing water or wash out prior to setting Wind Limitations:  Protect mortar if wind will d...
  • Weather Restrictions: Masonry based weather proofing coatings (parging)

    Connect to your favourite weather forecaster and look for the following conditions:   Category: Masonry     Product: Masonry based weatherproofing coatings Temperature Limitations: Use above +7 C (+45 F) Rain Limitations: No rain until hardened -- about 8 hours Wind Limitations:  High wind c...
  • Weather Restrictions: Crystalline growth waterproofing products

    Connect to your favourite weather forecaster and look for the following conditions:   Category: Concrete     Product: Crystalline growth waterproofing products Temperature Limitations: Use above +2 C (+35 F)  and below +21 C (+70 F) Rain Limitations: No rain until material is firm -- about 2 ...
  • Weather Restrictions: Bituminous foundation moisture control coating

    Connect to your favourite weather forecaster and look for the following conditions:   Category: Concrete     Product: Bituminous foundation moisture control coating Temperature Limitations: Water based products must be used above freezing -- Solvent based materials minimum -17 C (+1 F) Rain L...